Products Description
|
Product name |
Solenoid Valve |
|
Part number |
AT179491 |
| Machine model | 710K 410E |
|
Packing |
original or neutral |
|
MOQ |
1 PC |
|
Quality |
high quality |
|
Warranty |
3-6 months |
|
Shipping |
DHL, UPS, FedEx, Air, Sea, DDP |
|
Payment |
TT/Alibaba Trade Assurance/Credit card/Western Union/Alipay/Wechat |
DETAILED PHOTOS






What do We Sell?
We sell engine parts,like engine rebuild kit,full gasket,fuel injection pump,turbocharger,water pump fuel injector,and so on,we have electric parts like controllers,solenoid valves,monitor,sensors ect,we also sell hydraulic parts like final drives,hydraulic pump,besides,we have diagnostics tools ,seal kits,undercarriage parts and rubber parts for excavators and other heavy equipments.
In a world,no matter you are a shop owner or trader,or mechanic, here in our store, you can complete one-stop shopping,for your excavators,or fill your inventory.

Shipping Methods
- By express: DHL,UPS,FedEx,Aramex,TNT,EMS,SF express.
- By air to the airport.
- By sea to the port.
- DDP by air or by sea
- To your freight forwarder in China.

FAQ
Q:Do you have your own factory or partners?
A: We operate our own factory in China and partner with top-tier suppliers for stable supply chains.
Q:How to verify part compatibility?
A:Provide your excavator model ,pictures and part number for verification.
Q:Which excavator brands are your parts compatible with?
A:Compatible with major brands like Caterpillar, Komatsu, Hitachi, Volvo, Kobelco,Doosan,etc.
Q:What shipping options are available?
A:Express (DHL/UPS/Fedex), sea freight, air freight
Q:Are products tested before shipment?
A:All products undergo 100% functionality testing before shipment to ensure they are fully functional.
Four Core Functions of Solenoid Valve
Burned-out or aged electromagnetic coil
Causes:
Prolonged overload operation, unstable voltage, internal moisture, or aging insulation can cause the coil to overheat, short-circuit, or open-circuit. Symptoms include valve malfunction, severe coil overheating, or a burnt smell.
Repair:
Replace the entire electromagnetic coil assembly. Use a multimeter to measure the coil resistance and compare it with the standard value to confirm damage. When replacing, always use an original or certified compatible coil with the same voltage and power specifications, and ensure the plug connection is secure and waterproof.
01
Sticking or between valve core and orifice
Causes:
Hydraulic oil contamination is the main cause. Impurities enter the gap between the valve core and valve orifice, causing obstructed movement or scoring/wear. Symptoms include slow valve operation, incomplete valve movement, or abnormal system pressure or flow.
Repair:
Dissassemble, clean, or replace the valve core/valve body. If the sticking is not severe, thoroughly clean the valve core and valve orifice to remove foreign objects. If there is visible wear or scoring grooves, the worn parts must be replaced. After repair, the system hydraulic oil must be thoroughly filtered or replaced and the pipelines cleaned.
02
Seal Failure
Causes:
Prolonged exposure to oil, pressure, and temperature can cause rubber seals to age, harden, deform, or crack, leading to external leakage or internal oil cross-contamination of the valve body, affecting performance and polluting the environment.
Repair:
Replace all seals. When disassembling the valve body, use specialized tools to avoid damaging the sealing grooves. Use original or equivalent material and specifications seals, ensuring correct installation and no twisting. If necessary, apply a small amount of clean hydraulic oil to the seals to aid installation.
03
Return Spring Fatigue or Breakage
Causes:
Frequent compression and release during electromagnetic on/off cycles can cause metal fatigue in the spring, leading to weakened elasticity or breakage. This will affect the valve core's return speed and positional accuracy, causing response delay.
Repair:
Replace the return spring. After disassembly, inspect the spring for permanent deformation, cracks, or breakage. When replacing, always select a spring with the same elastic coefficient and size. Incorrect springs will alter the valve's opening and closing characteristics, affecting the response and control accuracy of the entire hydraulic system.
04
Hot Tags: 12v at179491 solenoid valve for machine 710k 410e model, China 12v at179491 solenoid valve for machine 710k 410e model manufacturers, suppliers, factory